Full 5V0-21.20 Practice Test and 77 unique questions with explanations waiting just for you!
Master Specialist HCI 2020 Dumps 5V0-21.20 Exam for Full Questions - Exam Study Guide
NEW QUESTION 21
An architect has been asked to design a vSAN Stretched Cluster. The architect will configure Microsoft Active Directory to replicate between a server on Site A (preferred) and a server on Site B (non-preferred). The architect must minimize the amount of raw storage capacity used.
Which storage policy needs to be applied to the Active Directory server on site A?
- A. None - stretched cluster
- B. Dual site mirronng
- C. None - standard cluster
- D. None - keep data on Preferred
Answer: D
NEW QUESTION 22
A customer environment includes:
* 4-node vSAN cluster
* 5 SQL servers with an OS virtual disk and database virtual disk
* Current policy uses the vSAN Default Storage policy
A vSAN administrator has created a new policy with fault tolerance method of Erasure Coding with Failures to tolerate equal to 1. The administrator will apply this new policy to the OS disk only.
Considering this scenario, which two statements are true? (Choose two.)
- A. vSAN policies can only be applied to entire VMs.
- B. This policy will require additional transitional space, until all objects are recreated.
- C. The policy can't be applied as there are not enough nodes to comply with the policy.
- D. The object tree will have to be rebuilt when the policy is applied.
- E. The policy will result is size reduction and only will require 1.5x space instead of 2x.
Answer: B,D
NEW QUESTION 23
An infrastructure architect is designing a vSAN Cluster that must satisfy these requirements:
* support storage policies with 2 failures - RAID-1 (Mirroring)
* support storage policies with 2 failures - RAID-6 (Erasure Coding)
virtual machines must maintain compliance with the storage policy rules above when one host is in maintenance mode with full data migration What is the minimum number of hosts needed to achieve these design requirements?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 24
A company Is using vSAN Data At Rest Encryption. vCenter is placed on a separate management cluster with external storage. The external storage system has suffered from a disk error and the vCenter Server restore from backup has been unsuccessful, due to media errors.
Considering the scenario, which statement Is true?
- A. A new vCenter can be deployed using the existing KMS profile and associated with the existing vSAN encrypted clusters.
- B. The data within the vSAN datastore is lost, if the hosts are powered off.
- C. All encrypted disk groups become unmounted and remain offline until vCenter Server is back online.
- D. The VMs on the vSAN datastore need to be migrated to another datastore as quickly as possible to prevent data loss.
Answer: D
NEW QUESTION 25
An administrator is designing a network for a vSAN cluster.
What is the recommendation for the cluster's network configuration?
- A. Create separate distributed switches for Management, vSAN, and vMotion.
- B. Create separate VMkernel ports for Management, vSAN, and vMotion.
- C. Set shares within Network I/O Control (NIOC) to prefer vMotion traffic over vSAN traffic.
- D. Set the Multicast filtering mode in the virtual distributed switch to IGMP/MLD snooping.
Answer: B
NEW QUESTION 26
A storage administrator working for a large enterprise is consolidating multiple locations into 2 data centers running on a new HCI platform. vSphere Replication has been used with vSAN to migrate a large amount of data between two separate locations with high latency links. The administrator has been asked to plan the VM migration using vSphere Replication failover. The plan will involve stopping replication, failing the workloads over to the second site, and preparing for the next migration of VMs.
Which two statements are correct in this scenario? (Choose two.)
- A. vSphere replication does not add additional load to the Storage solution.
- B. When using vSphere Replication and vSAN, only virtual machines that are powered on are automatically replicated.
- C. vSphere Replication will automatically run a post-failover clean up task following replication being stopped.
- D. VMware Site Recovery Manager is required to perform the failover.
- E. There will be a post migration task to manually cleanup vSAN namespaces at the target data store.
Answer: A,C
NEW QUESTION 27
Which two are requirements for Kubernetes cluster virtual machines when leveraging vSphere Cloud Native Storage (CNS)? (Choose two.)
- A. virtual machine hardware version 15 or higher
- B. set the disk.EnableUUID advanced setting to
- C. Set the Disk Mode to Independent
- D. minimum of 4 vCPUs per node
- E. configure UEFI firmware
Answer: A,B
NEW QUESTION 28
Which is true about vSAN fault domains?
- A. A vSAN Stretched cluster has two primary fault domains.
- B. A vSAN Stretched Cluster has three primary fault domains.
- C. A 2-node vSAN Cluster has two primary fault domains.
- D. A vSAN Standard Cluster cannot be configured with fewer than 3 fault domains.
Answer: A
NEW QUESTION 29
Refer to the exhibit.
An administrator is managing a 4-node, hybrid vSAN cluster. One of the hosts in the cluster went offline.
Referencing the information displayed in the resyncing objects section of the vSAN UI, what is the current state of this cluster?
- A. Objects will be resynchronized when the Object Repair Timer expires.
- B. Resync Throttling has caused data resynchronization scheduling.
- C. Metadata resynchronization is scheduled to occur every 60 minutes.
- D. Offline host reconnected to the cluster and all objects are synchronized.
Answer: C
Explanation:
Explanation/Reference: https://core.vmware.com/resource/vsan-2-node-guide#sec11-sub3
NEW QUESTION 30
Refer to the exhibit:
The vSAN Health service is reporting VSAN Cluster Partition' warning. The partition list shows all hosts from rack 1 in a single partition and all hosts from rack 2 in another partition.
Which hardware component requires investigation to resolve the cluster partition?
- A. vSAN Master node
- B. core switch
- C. ToR switches
- D. NICs on each host in Rack 2
Answer: C
NEW QUESTION 31
An administrator is planning to upgrade from vSAN 6.6 to a newer version. Which is recommended for this upgrade?
- A. From the command line, turn multicast off in order to migrate to unicast mode.
- B. vSAN VASA Providers must be changed to be internally managed prior to the upgrade.
- C. Certificates used by VASA must be upgraded on vSphere prior to the upgrade.
- D. Perform a rolling upgrade of the hosts via vSphere Update Manager after upgrading vCenter.
Answer: D
NEW QUESTION 32
An administrator is working with an application which has these characteristics:
* latency sensitive
* database striped over multiple virtual disks
* no application redundancy
Which storage policies meet the VM performance and cluster constraint while protecting against at least 1 failure?
- A. RAID 5, Stripe Width 1
- B. RAID 1, Stripe Width 2
- C. RAID 6, Stripe Width 2
- D. RAID 1, Stripe Width 1
Answer: A
NEW QUESTION 33
A 3-node All-Flash vSAN cluster has this configuration:
* One disk group per host
* All disk groups have identical make & model disks of an 800GB NVMe SSD cache and 2x 4TB SAS SSDs each An administrator has been tasked with expanding storage capacity by adding one additional disk group with this configuration:
1.6TB SAS SSD cache and 1x 4TB SAS SSDs
Assuming all the disks are compliant with the vSAN HCL, which is true?
- A. The additional disk group will generate an 'Advanced vSAN Configuration in sync' health check warning.
- B. The additional disk group would work and be fully supported by VMware support.
- C. The additional disk group would make this cluster an unsupported configuration.
- D. The additional disk group would not be possible as vSAN would not allow it.
Answer: C
NEW QUESTION 34
Which step can be avoided when replacing a capacity tier device on a controller with passthrough mode and support for hot-plug?
- A. Add the new disk to the disk group.
- B. Replace the physical drive.
- C. Remove the disk from the disk group.
- D. Shut down the host.
Answer: B
Explanation:
Explanation/Reference: https://docs.vmware.com/en/VMware-vSphere/6.5/virtual-san-66-administration-guide.pdf (31)
NEW QUESTION 35
Which storage policy can be assigned to virtual machines In a 5-node, all flash vSAN cluster, to provide the highest level of redundancy?
- A. 2 failures - RAID-6 (Erasure Coding)
- B. 1 failure - RAID-5 (Erasure Coding)
- C. 2 failures - RAID-1 (Mirroring)
- D. 3 failures - RAID-1 (Mirroring)
Answer: A
NEW QUESTION 36
An All-Flash vSAN cluster has 4-nodes with this disk group composition on each host:
* 1 x 800 GB SAS SSD
* 6 x 3.84 TB SATA SSD
An administrator observes that in an All-Flash cluster, the Write
Buffer Free Percentage is consistently low. As a result there is increased latency experienced by the workloads.
Which remediation steps will resolve this issue?
- A. Add a second disk group with a new cache device and distribute the capacity disks equally.
- B. Add a second cache device to the same disk group to increase the caching size.
- C. Replace the existing cache device with a larger cache device.
- D. Modify advanced vSAN configuration parameters to utilize the complete 800 GB for caching.
Answer: B
NEW QUESTION 37
Which three should be taken into consideration when configuring a Stretched Cluster? (Choose three.)
- A. number of objects
- B. latency between sites
- C. bandwidth between sites
- D. geographical distance
- E. vSphere version
Answer: A,D,E
NEW QUESTION 38
The vSAN Health Check 'Hosts disconnected from vCenter Server' is reporting an error state for one host in the vSAN Cluster. All other health checks in the Network category are in a green state.
Which VMware recommended remediation task should be taken by the administrator?
- A. Right-click the affected host and click Connection > Connect.
- B. Restart the vSAN Management Daemon.
- C. Right-click the affected host and click Remove from Inventory.
- D. Configure a vSAN-enabled VMkernel port on the affected host.
Answer: B
NEW QUESTION 39
Which should be verified before enabling de duplication and compression?
- A. All hosts are in maintenance mode.
- B. Autoclaim mode is enabled.
- C. Adequate space is available.
- D. Ensure disk groups are balanced.
Answer: B
NEW QUESTION 40
Refer to the exhibit:
The vSAN Health service is reporting VSAN Cluster Partition' warning. The partition list shows all hosts from rack 1 in a single partition and all hosts from rack 2 in another partition.
Which hardware component requires investigation to resolve the cluster partition?
- A. vSAN Master node
- B. ToR switches
- C. core switch
- D. NICs on each host in Rack 2
Answer: D
NEW QUESTION 41
......
Authentic Best resources for 5V0-21.20 Online Practice Exam: https://www.testsimulate.com/5V0-21.20-study-materials.html