VMware HCI Master Specialist (5V0-21.20) Free Practice Test
Question 1
Which Kubernetes information is exposed in the vSphere Client to help a vSAN administrator filter Container Volumes based on their usage?
Correct Answer: B
Question 2
Which Kubernetes component must be configured to allow for dynamic provisioning of container volumes on vSAN?
Correct Answer: A
Question 3
A company Is using vSAN Data At Rest Encryption. vCenter is placed on a separate management cluster with external storage. The external storage system has suffered from a disk error and the vCenter Server restore from backup has been unsuccessful, due to media errors.
Considering the scenario, which statement Is true?
Considering the scenario, which statement Is true?
Correct Answer: C
Question 4
A vSAN administrator wants to implement end-to-end prioritization of vSAN traffic across the network in a shared network infrastructure that is using vSphere Distributed Switches (VDS).
Which two can help achieve this objective? (Choose two.)
Which two can help achieve this objective? (Choose two.)
Correct Answer: C,E
Question 5
During planned maintenance of a four-node vSAN cluster, an outsourced IT contractor accidentally removed a
2.5" SSD cache disk from one of the vSAN nodes. The storage policy has been configured with FTT=1 RAID
1, and the disk management UI marked the disk group as
Which remediation steps should the administrator select to ensure VMs become compliant with the storage policy as soon as possible?
2.5" SSD cache disk from one of the vSAN nodes. The storage policy has been configured with FTT=1 RAID
1, and the disk management UI marked the disk group as
Which remediation steps should the administrator select to ensure VMs become compliant with the storage policy as soon as possible?
Correct Answer: B
Question 6
An administrator arrives at work and begins their morning checks on a four node, all-flash vSAN Cluster.
They notice the vSAN datastore reached 99% capacity due to a single node failure.
How can the administrator provide temporary relief?
They notice the vSAN datastore reached 99% capacity due to a single node failure.
How can the administrator provide temporary relief?
Correct Answer: A
Question 7
A vSAN all-flash environment with these host specifications has reported high network latency, write latency, and faces degraded performance:
* One 1Gbps (vSAN, vMotion Traffic)
* One 1Gbps (Management, Fault Tolerance traffic)
Based on the specifications of each host, what is recommended to resolve the issue?
* One 1Gbps (vSAN, vMotion Traffic)
* One 1Gbps (Management, Fault Tolerance traffic)
Based on the specifications of each host, what is recommended to resolve the issue?
Correct Answer: C
Question 8
Which step can be avoided when replacing a capacity tier device on a controller with passthrough mode and support for hot-plug?
Correct Answer: B