Welcome to TestSimulate

Pass Your Next Certification Exam Fast!

Everything you need to prepare, learn & pass your certification exam easily.

365 days free updates. First attempt guaranteed success.

Cisco 500-920 Dumps Updated [Jan-2022] Get 100% Real Exam Questions! [Q17-Q37]

Share

[Jan-2022] Pass Cisco 500-920 Exam in First Attempt Guaranteed!

Full 500-920 Practice Test and 42 unique questions with explanations waiting just for you, get it now!

NEW QUESTION 17
When it comes to pinning vNIC traffic from a UCS Server to the Fabric Interconnect uplink what configuration can you perform?

  • A. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect
  • B. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect
  • C. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect the server will fail to the matching uplink on the other Fabric Interconnect
  • D. You can configure Automatic Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the other Fabric Interconnect
  • E. You can configure Static Uplink Pinning. If an uplink interface fails on one Fabric Interconnect, the server will fail to the first available uplink on the same Fabric Interconnect

Answer: D

 

NEW QUESTION 18
An overvoltage condition has occurred on a UCS server However the Cisco IMC System Event Log (SEL) file is full What is the resulting fault logging action?

  • A. The overvoltage condition event will not be recorded in the SEL.
  • B. The oldest entry in the SEL will be overwritten by the overvoltage condition event
  • C. The newest entry in the SEL will be overwritten by the overvoltage condition event.
  • D. The SEL is not used to record server related events, such as overvoltage conditions.

Answer: A

 

NEW QUESTION 19
In Cisco UCS, there are several interfaces involved on the packet path from the vNIC through the adapter, IOM to finally reach Pi Which is the order of those interfaces, starting from the vNIC?

  • A. VIF, UIF, HIF, SIR NIF
  • B. HIF. SIF, VIF, UIF NIF
  • C. VIF, UIF, HIF, NIF SIF
  • D. HIF. NIF, UIF, VIF SIF

Answer: A

 

NEW QUESTION 20
Which statement is true when using SPAN for Fibre Channel (FC) Traffic?

  • A. When defining FC uplink port as the SPAN destination, system will automatically stop using that port as an uplink port
  • B. For FC SPAN sessions we do not have to specifically enable the monitoring session
  • C. FC port on Cisco UCS 6238UP can be used as a SPAN source
  • D. Any port can be used as a SPAN destination port Even if it is defined as Eth uplink port it will be automatically converted to FC uplink port

Answer: C

 

NEW QUESTION 21
The UCS Chassis Discovery Policy has been set to four and a new chassis is connected with two links What is the resulting chassis recognition action?

  • A. The Chassis Discovery Policy will automatically reset to two links, since it always tracks the physical connections
  • B. The chassis will not be recognized
  • C. The chassis will be recognized and both links will be active
  • D. The chassis will be recognized but only one of the links will be active.

Answer: B

 

NEW QUESTION 22
When booting up a Cisco UCS Server you want to see boot time diagnostic messages of the POST, what action is required for you to do so?

  • A. Restart the Server
  • B. Disable Fast Boot on the Server's Service Profile
  • C. Enable Quiet Boot on the Server's Service Profile
  • D. Enable Quiet Boot on the Server's BIOS
  • E. Disable Fast Boot on the Server's BIOS

Answer: C

 

NEW QUESTION 23
After installing a new UCS M4 server, which two Cisco Integrated Management Controller connectivity options do you have? (Choose two )

  • A. Out-of-Band Access
  • B. XML API Access
  • C. SNMP
  • D. In-band Access
  • E. Web Access

Answer: B,D

 

NEW QUESTION 24
When server is booting from SAN, which command verifies the PLOGI sessions with the target?

  • A. Lunmap
  • B. FCMap
  • C. FCIist
  • D. Lunlist

Answer: D

 

NEW QUESTION 25
What are three possible causes of service profile association failure due to iSCSI configuration issue? (Choose three )

  • A. iSCSI Target out of configured range of services
  • B. Inappropriate network configuration
  • C. Misconfigured LUN. LUN masking
  • D. Misconfigured iSCSI parameters
  • E. Improperly assigned iSCSI Class of Service
  • F. Wrong WWNN

Answer: A,B,D

 

NEW QUESTION 26
In order to create an Inband Profile for Cisco Integrated Management Controller (IMC) connectivity, what do you need to perform first?

  • A. Create a Management IP Pool, a MAC Address Pool, and a VLAN Pool
  • B. Create an IPMI Policy
  • C. Create different VLANs, with different VLAN IDs
  • D. Create a Management IP Pool, a VLAN. and a VLAN Group
  • E. Create a Service Profile

Answer: E

 

NEW QUESTION 27
The command show interface veth 705 is telling you that the bound interface is Ethernet 3/1/2 What is the location of the blade that has veth 705 associated to it?

  • A. Chassis 3. Slot 2
  • B. Chassis 3, Slot 1
  • C. There is not enough information
  • D. Chassis 1. Slot 2

Answer: B

 

NEW QUESTION 28
When troubleshooting, which option is the primary uses of the SCOPE command?

  • A. To access the log files on the virtual machines
  • B. To access the log files that reside in a component
  • C. The SCOPE command is not helpful in this case
  • D. To access the log files on the log server

Answer: B

 

NEW QUESTION 29
Which two formats can be configured for Cisco's Call Home email message? (Choose two )

  • A. Full text
  • B. JSON
  • C. CSV
  • D. XML

Answer: A,D

Explanation:
Call Home Message Formats The Call Home feature offers the following message formats: * Short Text - Suitable for pagers or printed reports. * Plain Text - Full formatted message information suitable for human reading. * XML - Matching readable format using Extensible Markup Language (XML) and Adaptive Markup Language (AML) document type definitions (DTDs). The XML format enables communication with the Cisco TAC. For user-defined destination profiles, the format options are long-text, short-text, or XML. The default is XML. For the predefined Cisco TAC profile, only XML is allowed.
Reference:
http://www.audentia-gestion.fr/cisco/smart-call-home-feature-guide-1611.pdf

 

NEW QUESTION 30
Which are two benefits of integrating Cisco UCS C-series servers with Cisco UCS Manager? (Choose two ) Cisco UCS Manager provides the ability to automatically update C-series firmware and device drivers from a single global interface.

  • A. Cisco UCS Manager can automatically power on and off servers to scale elastically according to application performance demands
  • B. Cisco UCS Manager is able to act as a common centralized management platform for both blade and rack servers in a single domain.
  • C. Cisco UCS Manager uses service profiles and resource pools to allow the deployment of multiple servers with a single common template
  • D. Cisco UCS Manager provides the ability to manage C-series in multiple physical domains from a single global interface

Answer: B

 

NEW QUESTION 31
Which two ports on a pair of Cisco Fabric Interconnects must be properly cabled for the pair to form a cluster? (Choose two )

  • A. L1 > L1
  • B. L2 > L2
  • C. L1 > L2
  • D. L2 > L1

Answer: A,B

 

NEW QUESTION 32
In a Cisco UCS Manager, if all KVM sessions to each server fail to start, what is likely causing the problem?

  • A. The Fabric Interconnect to which you are connected has a problem
  • B. Cisco UCS Manager has a problem
  • C. The I/O Modules in the chassis are the problem
  • D. The workstation you are using to connect to the KVM session is the problem

Answer: D

 

NEW QUESTION 33
......

Get Latest 500-920 Dumps Exam Questions in here: https://www.testsimulate.com/500-920-study-materials.html