Question 1
An office space with 10 ft (3 m) high ceilings is designated as a Light Hazard Occupancy. It is determined that the area of sprinkler operation is 1,500 ft2 (139 m2). Assuming the conditions are satisfied for design area reduction, what can the area of sprinkler operation be reduced to for quick response sprinklers?

Correct Answer: C
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 2
The FPE has indicated that a vertical opening shall be protected by closely spaced sprinklers in combination with a draft stop installed per code. The sprinklers will be spaced 6 ft (1.83 m) on center. What is the minimum gpm discharge required per sprinkler head?

Correct Answer: D
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 3
For an Extra Hazard Group 1 remote area of 2,500 ft2 (232.25 m2) using fire sprinklers with a coverage area of
92 ft2 (8.547 m2), how many gallons per minute of water are required per sprinkler?

Correct Answer: B
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 4
Which of the following is a mandatory referenced publication in NFPA 13?

Correct Answer: D
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 5
What is the minimum flow rate required for the most hydraulically remote Class I standpipe?

Correct Answer: D
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 6
A owner of a new warehouse wishes to store a Class III product in ordinary cardboard boxes that contain 45 percent by volume expanded plastic. What is the commodity classification?

Correct Answer: D
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 7
A sprinkler with a blue glass bulb represents a temperature classification of

Correct Answer: B
Question 8
When backflow prevention valves are installed on existing pipe scheduled systems, the friction losses of the device shall be accounted for when determining

Correct Answer: B
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 9
What is the minimum calculated design area for a light hazard sprinkler system protecting an open office space with a noncombustible acoustic ceiling tile installed 6 in. (150 mm) below the bottom of solid wood joists?

Correct Answer: B
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).
Question 10
When field acceptance testing a fire pump with a variable speed pressure limiting control, the pump shall be tested in variable speed mode at

Correct Answer: C
Explanation: Only visible for TestSimulate members. You can sign-up / login (it's free).